| Specifications | |
| Bandwidth | 60MHz |
| Sample rate(Real time) | 250MS/s |
| Horizontal Scale(S/div) | 5ns/div~100s/div, step by 1~2~5 |
| Rise time (at input, typical) | ≤5.8ns |
| Channels | Dual |
| Display | 3.7 inch color display with TFT panel (640×480 pixels) |
| Input impedance | 1MΩ±2%in parallel with 15pF±5pF |
| Probe attenuation factor | 1X,10X,100X,1000X |
| Max. input voltage | 400V (PK-PK) DC + AC PK-PK, 1MΩ input impedance, Probe attenuation 10:1 |
| Record length | Max.6000 points on each channel |
| Interpolation | (sin x)/x |
| Input coupling | DC, AC, GND |
| Acquisition modes | Sample, Peak Detect and Average |
| Vertical resolution (A/D) | 8 bit (2 channels simultaneously ) |
| Vertical sensitivity | 5mV/div~5V/div(at input) |
| DC gain accuracy | ±3% |
| DC accuracy (Average) | Average>16:±(5% reading+0.05div) for ΔV |
| Trigger type | Edge, Video, Alternate |
| Trigger mode | Auto, Normal, Single |
| Trigger level | ±6 divisions from screen center |
| Waveform math | +, -, ×, ÷, FFT |
| Waveform storage | 4 waveforms |
| Communication interface | USB |
| Cymometer | Available |
| Power supply | 100V-240V AC, 50/60Hz |
| Multimeter Specification | |
| Full scale reading | Diode |
| Input Impedance | On/Off measurement |
| Capacitance | 51.2nF-100uF:±(3%±3 digit) |
| Voltage | VDC:400mV,4V, 400V: ±(1±1digit) Max. input: DC 1000V, VAC:4V,40V,400V:±(1±3digit) Frequency:40Hz-400Hz, Max. input: AC 750V(virtual value) |
| Current | DCA:40mA, 400mA:±(1.5%±1 digit) 10A:±(3%±3digit) DAA:40mA±(1.5%±3digit) 400mA:±(2±1digit) 10A:±(3%±3digit) |
| Impedance | 400Ω:±(1%±3digit), 40Ω |
| Included Accessories | |||
|
|||
| Specifications | |
| Bandwidth | 60MHz |
| Sample rate(Real time) | 250MS/s |
| Horizontal Scale(S/div) | 5ns/div~100s/div, step by 1~2~5 |
| Rise time (at input, typical) | ≤5.8ns |
| Channels | Dual |
| Display | 3.7 inch color display with TFT panel (640×480 pixels) |
| Input impedance | 1MΩ±2%in parallel with 15pF±5pF |
| Probe attenuation factor | 1X,10X,100X,1000X |
| Max. input voltage | 400V (PK-PK) DC + AC PK-PK, 1MΩ input impedance, Probe attenuation 10:1 |
| Record length | Max.6000 points on each channel |
| Interpolation | (sin x)/x |
| Input coupling | DC, AC, GND |
| Acquisition modes | Sample, Peak Detect and Average |
| Vertical resolution (A/D) | 8 bit (2 channels simultaneously ) |
| Vertical sensitivity | 5mV/div~5V/div(at input) |
| DC gain accuracy | ±3% |
| DC accuracy (Average) | Average>16:±(5% reading+0.05div) for ΔV |
| Trigger type | Edge, Video, Alternate |
| Trigger mode | Auto, Normal, Single |
| Trigger level | ±6 divisions from screen center |
| Waveform math | +, -, ×, ÷, FFT |
| Waveform storage | 4 waveforms |
| Communication interface | USB |
| Cymometer | Available |
| Power supply | 100V-240V AC, 50/60Hz |
| Multimeter Specification | |
| Full scale reading | Diode |
| Input Impedance | On/Off measurement |
| Capacitance | 51.2nF-100uF:±(3%±3 digit) |
| Voltage | VDC:400mV,4V, 400V: ±(1±1digit) Max. input: DC 1000V, VAC:4V,40V,400V:±(1±3digit) Frequency:40Hz-400Hz, Max. input: AC 750V(virtual value) |
| Current | DCA:40mA, 400mA:±(1.5%±1 digit) 10A:±(3%±3digit) DAA:40mA±(1.5%±3digit) 400mA:±(2±1digit) 10A:±(3%±3digit) |
| Impedance | 400Ω:±(1%±3digit), 40Ω |












Hiển thị 1–12 của 4991 kết quảĐã sắp xếp theo mức độ phổ biến